Available Technologies by Category
Voice-Activated Robotic Exoskeleton for Rehabilitation and Assistance
  • Voice-activated movement controlled by the patient
  • Integrated smartphone application to recommend exercises and schedules
  • Quantitative performance metrics and analysis sent to the physical therapist
8130
Ultra-High Resolution Multimodal Imaging System
  • Integrative perspective imaging - topological and chemical imaging of complex biological samples and heterogeneous nanomaterial interfaces with sub-micrometric resolution
  • Improved spatial resolution - system provides chemical imaging resolution of ~ 250 nm and electron microscopy topological resolution of ~ 50 nm.
  • Accuracy in analytics - analysis at the level of a single cell or with subcellular resolution has been seen as a next frontier in innovative approaches to discovery
8300
2D Array Device
  • Simple – does not require microstructure fabrication or periphery equipment, such as pressure-driven pumps to operate
  • Unique – loading method enables rapid sample loading and high-percentage sample isolation simultaneously
  • Cheaper – improvements in efficiency and robustness reduce complexity and overhead expenses
8253
Disposable Impedance Biosensor for Cell Manufacturing
  • Multi-point measurements- provide tempo-spatial profiles of culture attributes and can print a wide range of conductive and insulating materials on both rigid and flexible substrates with non-planar surfaces
  • Wireless - collects the signal wirelessly via printed antennas to simplify the integration to different types of existing bioreactor technologies
  • Safe - system does not apply contact, and minimizes any chance of harm or contamination to affect the cell culture
8270
Equipment-Free Quantification in Point-of-Care Diagnostic Assays
  • Field-deployable robustness: uses reference reactions to accurately measure biomarker levels without expensive or cumbersome equipment   
  • Lower cost: quantification does not require expensive technology
7992
3D Light-Field Endoscopy Using a Gradient Index Lens Array
  • Measurements: system achieves 'true quantitative' 3D information
  • Imaging and visualization: system brings a great potential for fast 3D quantitative imaging, visualization, and synthesis of the focal stacks
  • Material: method is glass-free
8283
Precision Needle Positioning Robotic System for MRI Guided Injection
  • Increased accuracy — robot capable of less than 100 micron accuracy
  • Increased speed — faster targeting of injection locations
8246
Spatial Tracking of Catheters in Interventional MRI
  • Increased safety — eradicates RF induced heating while providing position of catheters in the body during iMRI procedures
  • Simultaneous measurements — offers temperature measurements, orientation, and other parameters
7952
Guided Injection of Charged Cargo for Intracellular Delivery
  • Novelty – use of an electrically-charged liquid beam of electrospray
  • Improved control – control of action on the scale of single cell/single pores
  • Diversity – arbitrary diverse set of cargo
8275
Instrumented Ankle-foot Orthosis
  • User friendly – fully wearable and portable
  • Objective data – enhances patient outcomes
7547
Wireless Neurovascular Monitoring System
  • Minimally invasive: minimal impact on hemodynamics (dynamics of blood flow)
  • Flexible and stretchable: able to conform to complex vessel geometry
  • Longer range: improved wireless detection range
7908
Water-Soluble Mold for Sample Analysis
  • Inexpensive: difference in materials used from existing practices, lowers manufacturing costs  
  • Universal adoption: no requirement of expensive cleanrooms facilities and associated personnel
  • Environmentally: conscious- non-toxic process eliminates need for organic solvent and waste treatment
8138
A Technique for Integrating Photographs for Medical Imaging Examinations
  • Prevents the application of incorrect patient identification at the time of medical image generation
  • Allows the correlation of serial imaging studies by ensuring that all studies are from the same patient
  • Avoids the generation of incorrect reports
6402
Constellation Diagrams to Model Biomolecules’ Electrostatic Properties
  • Low computational cost – reduces algorithm run-time via reduction in complexity of computing molecular electrostatic properties
  • Digitally encoded molecular electrostatic properties – utilizes orthogonal basis functions
  • Visual toolsets- to analyze molecular electrostatic properties and generates 4D plots of molecular electrostatic properties
8245
Storage Media for Determining Optimal Respiratory Treatment
  • Automatically determines optimal radiation therapy treatment phase
  • Enables higher, more effective radiation dosage amounts
  • Minimizes unnecessary radiation to normal surrounding tissues
6926
Self-Assembling Peptides for Cell and Notch-Ligand Delivery
  •  Hydrogels are biocompatible, easy to modify and biodegradable 
  • Could be applied in a more platform-like manner by incorporating other peptides to repair cardiac or other tissues
  • The peptide sequence activates signaling of pathways  improving the growth or replication of tissue or cells 
6480
Purification of Cell Mixtures Using Molecular Beacons
  • Purified cardiomyocytes can be used to regenerate damaged cardiac tissue in vivo
  • This method can be used to purify other types of stem cell derivatives
  • It can also be used to develop pure laboratory cell cultures for pharmacologic testing and research 
6463
A Screening Method to Detect Ovarian Cancer
  • Early stage detection
  • Highly accurate
  • Minimally invasive
7028
Microfluidic Platform for Phase Separation of Aqueous Solutions
  • Efficient workflow-  sample removal and analysis can be performed without manual oversight
  • Smaller sample size- less sample volume required alleviating dilution of low concentration solutions that is common in alternative sample preparation workflows
  • Faster process- thermoelectric cooling can induce separation in a matter of seconds with precision and tunability
8247
Compositions & Methods for Using NADH Oxidases
  • Biocatalysis is used in many industries including food, bioenergy, & pharmaceutical.
  • Recycling cofactors is necessary to control costs of biocatalysis reactions.
  • NADH oxidases convert NADH to NAD+, a major cofactor involved in biocatalysis.
4698