Available Technologies by Category
OptiFlo - A Single Ventricle Heart Repair Device
  • Improved quality of life­– optimizes blood flow and improves post-operative results by reducing recovery time
  • Assistive– reduces work for single ventricle
  • Controllable – proposed device regulates blood flow and pressure
3080
Disposable Cassette for Dialysis
  • Efficient- designed to minimize human error and reduces set-up time of dialysis treatment
  • Automated- enables automated dialysis mode selection using radio frequency identification
  • Disposable-  eliminates potential contamination in patient treatment

 

7111
Wearable Robotic Limb
  • The limb uses Artificial Intelligence and machine learning to understand what the user wants it to do and how to perform the required tasks in a changing environment
  • The limb’s movements are modeled based on human motions and therefore operate smoothly and look natural.
  • Proprietary multi-limb mounting design
7108
Grain Structure of Stainless Steel for Anti-Wetting Properties
  • Utilizes intrinsic grain structures of stainless steel to modify surface wettability
  • More efficient fluid transport and reduced energy consumption
  • Does not require the deposition of additional coatings
7096
Microfluidic Platform for High-Density Cell Delivery
  • Allows for hundreds of cells to be immobilized on a very small footprint- including non-adherent cells
  • Can analyze cell response at a single-cell resolution
  • Can simultaneously observe cell response and generate chemical cues- allows for observation of immediate cell response
5691
Methods for Generating Functional Therapeutic Cells
  • Novel – No present technology exists
  • Versatile – Can be adapted to suit a variety of diseases, human and animal
  • Targeted – Antigen-binding qualities within the B cell allow for highly specific therapies
7080
Generating Power via High-Efficiency Electrochemical Converter
  • Lower cost: The working fluid and storage materials are inexpensive.
  • Multifunctional: Multiple functions (e.g., solar conversion, thermal storage, electrochemical storage) can be integrated in a single system.
  • High efficiency: This device’s heat-to-electricity conversion has the potential to be twice what has been achieved previously.
7065
Non-contact vital sign detection
  • Automatically adjusts the feedback signals to suppress the noise when the measurement environment changes
  • Improves SNR by 50% at 50 cm when compared to an unlocked system
  • Detects heartbeat at 250 cm, more than twice the distance of the unlocked system
7064
Method for Preconcentration and Capture of Target Bacteria
  • Offers an inexpensive and rapid method for sample pre-concentration to improve food safety assays
  • Provides enhanced mixing and a high probability of target bacteria capture
  • Enables detection of low concentrations of target bacteria
7054
Ultra-Compact, Low-Power THz Radio
  • A THz fully integrated super-harmonic (2nd harmonic) regenerative receiver architecture, which detects the incoming THz signals and injection-locks to a regenerative receiver operating at a lower frequency
  • Reduces power consumption and improves the efficiency for THz signal generations
  • Employs a bidirectional and circuit-sharing architecture, so the THz receiver and the THz transmitter share the same oscillator operating at half the frequency
7053
Dual-Energy Computed Tomography Through Primary Beam Modulation
  • More affordable than currently available comparable DECT components.
  • Eliminates the need for two scans, resulting in a shorter imaging time and reducing issues associated to patient motion during scans.
  • Compatible with most CT scanners, including cone-beam CT.
7038
Electroactive Polymers with Rapid Switching Rates
  • Environmentally friendly: Aqueous/Organic processing is safer than the aromatic hydrocarbon and chlorinated solvents typically used.
  • Higher levels of electric power: Films made with this technology have significantly faster redox switching rates of up to 10V/s.
  • Versatile: Various electrolyte systems have been successfully tested, including organic, aqueous, the spinal fluid analog Ringer’s solution, and even commercially available sports drinks.
7035
A Mobile-to-Mobile Remote Computing Protocol for Mobile Computing Devices
  • Supports multi-touch mobile-to-mobile interaction with an order of magnitude increase in supported gestures.
  • Enables rich context transfer between remote mobile devices, and enables the client to experience the remote client’s context by providing access to all the sensor data on the remote client.
  • Compression scheme used is optimized to mobile device operating conditions such as application demands on CPU load, memory usage, and available network bandwidth.
7032
3D Printed Tissue-Mimicking Phantoms
  • Fabricates patient-specific tissue-mimicking phantoms with accurate biomechanical properties, in addition to accurate geometric properties
  • Associates biomechanical properties with gender, age, and other physiological/pathological conditions of the patient
7339
Stretchable Electronic Materials and Devices
  • Process is a readily implemented approach
  • Films can be stretched by 100% with retention of their high charge carrier mobility
  • Fabrication can be done with commercially available materials
7612
Sol-Gel Films and High Energy Capacitor Device
  • Sol-gel materials are a targeted research area for thin film energy storage and enhanced storage capabilities for wide variety of applications
  • All solution-processing including ready-to-spin recipes
  • Compatible with flexible substrates and roll-to-roll processing
6993
3D Printed Auxetic Scaffolds for Tissue Engineering
  • Faster cell growth rate- decreases average cell age in the finished product and increases vitality
  • Affordable and timely approach for regenerating tissues and replacing native tissues
  • Continuous entry and circulation of nutrients results in less variability between cells
7335
Motor Function Recovery System for Stroke Patients
  • Unconventional: Passive stimulation unlike traditional therapy or rehabilitation
  • Tactile: No electrostimulation, more comfortable to patients
  • Convenient: Little to no effort/attention required
7689, 7692, 7693, 7694, 7695